What does 49 CFR 40.83 (How do laboratories process incoming specimens?) require?

Generated guidance. Confirm the source and its applicability before you act. How we check sources.

As Ask X3, your fleet-compliance assistant, here is what 49 CFR 40.83 requires laboratories to do when processing incoming DOT specimens:

* Authorized CCF Copies: You are authorized to receive only Copy 1 of the Custody and Control Form (CCF). You must not receive other copies of the CCF or any alcohol testing form copies.

* HHS Guidelines: You must comply with applicable HHS Guidelines on accessioning and processing drug specimens.

* Inspection for Fatal Flaws: You must inspect each specimen and CCF for specific "fatal flaws," which include:

* No CCF provided.

* A specimen was collected, but no specimen was submitted with the CCF.

* No printed collector's name and no collector's signature.

* Two separate collections performed using a single CCF.

* Specimen ID numbers on the bottle and CCF do not match.

* The specimen bottle seal is broken or shows tampering (unless the split specimen can be redesignated).

* Insufficient specimen amount in the primary bottle for analysis (unless redesignated).

* For an oral fluid collection, an expired device was used.

* For an oral fluid collection, the collector failed to enter the expiration date in Step 4 of the CCF, and the laboratory cannot determine it by inspecting Bottles A and B.

* Handling Fatal Flaws: If a fatal flaw is found, document your findings, stop the testing process, and report the result in accordance with § 40.97(b)(3).

* Missing Collector Signature: If the collector's signature is missing from the certification statement in Step 4 of the CCF, document the flaw, continue testing, retain the specimen for at least 5 business days from when correction action was initiated, attempt to correct it using § 40.205(b)(1), and reject/report the test if it remains uncorrected.

* Unchecked Temperature: If a urine specimen temperature was not checked and the "Remarks" line has no entry about it being out of range, attempt to correct it under § 40.208 for five business days before reporting the result.

* Improper Forms: If an improper form was used (such as a non-Federal or expired Federal form), attempt to correct it under § 40.205(b)(2), retain the specimen for at least 5 business days, and reject the test if not corrected.

* Split Specimen Issues & Redesignation: If the split specimen does not accompany the primary, has leaked, or is unavailable, you must still test the primary specimen following § 40.175(b). You may redesignate primary and split specimens (swapping Bottle A and B roles by marking, initialing, and dating the bottles) under specific conditions, such as a leaked primary bottle, labeling mix-ups, the laboratory opening the split bottle instead of the primary, or a broken primary seal, provided sufficient specimen exists.

* Documentation of Flaws: Make a notation on Copy 1 of the CCF (Step 5a) and internal chain of custody documents for any fatal or correctable flaw.

*(Reference: 49 CFR 40.83)*

§ 49 CFR 40.83 · eCFR ↗Sources retrieved: 1 retrieved CFR section

Related questions

What does 49 CFR 40.82 (What drugs do laboratories test for?) require? — Ask X3What does 49 CFR 40.79 (How is the collection process completed?) require? — Ask X3What does 49 CFR 40.87 (What validity tests must laboratories conduct on primary urine specimens?) require? — Ask X3What does 49 CFR 40.97 (What do laboratories report and how do they report it?) require? — Ask X3