What does 49 CFR 178.817 (Righting test) require?
Generated guidance. Confirm the source and its applicability before you act. How we check sources.
Based on 49 CFR 178.817, the righting test requires the following:
* Applicability: It applies to all flexible Intermediate Bulk Containers (IBCs) that are designed to be lifted from the top or side.
* Preparation: You must fill the flexible IBC to at least 95 percent of its capacity and to its maximum net mass, ensuring the load is evenly distributed.
* Test Method: With the flexible IBC lying on its side, lift it to an upright position—so it is completely clear of the floor—at a speed of at least 0.1 meters per second (0.33 feet per second). Use one lifting device, or two lifting devices if four are provided.
* Passing Criterion: There must be no damage to the IBC or its lifting devices that would make it unsafe to handle or transport.