What does 49 CFR 173.311 (Metal Hydride Storage Systems) require?
Generated guidance. Confirm the source and its applicability before you act. How we check sources.
Based on 49 CFR 173.311, transportable UN Metal hydride storage systems (UN3468) with pressure receptacles up to 150 liters (40 gallons) in water capacity and a maximum developed pressure of 25 MPa or less must meet the following requirements:
* Design and Testing: They must be designed, constructed, initially inspected, and tested in accordance with ISO 16111:2018, consistent with § 178.71(m). Alternatively, until December 31, 2026, they may conform to the older ISO 16111:2008(E) standard.
* Marking for Steel Liners: Steel pressure receptacles or composite pressure receptacles with steel liners must be marked per § 173.301b(f). This requires a steel UN pressure receptacle with an “H” mark if it is used for hydrogen-bearing gases or other gases that can cause hydrogen embrittlement.
* Requalification: They must be requalified at least every five years, following the procedures in ISO 16111:2018 or ISO 16111:2008 and as specified in § 180.207.