What does 49 CFR 178.275 (Specification for UN Portable Tanks intended for the transportation of liquid and solid hazardous materials) require?
Generated guidance. Confirm the source and its applicability before you act. How we check sources.
As a motor-carrier owner, according to 49 CFR 178.275, your UN portable tanks intended for transporting liquid and solid hazardous materials must meet specific requirements regarding design pressure, maximum allowable working pressure (MAWP), service equipment, bottom openings, pressure relief devices, and vacuum-relief devices.
Here are the practical requirements for your equipment:
* Design Pressure & MAWP: Your tanks must be designed and built to withstand specific pressure calculations based on the hazardous material's vapor pressure, partial pressure of air, and head pressure during filling, discharging, and transport. The MAWP must be at least equal to the design pressure and measured at the top of the shell.
* Service Equipment & Openings:
* All openings used for filling or discharging must have a manually operated stop-valve positioned as close to the shell as reasonably practicable.
* Tanks must have a manhole or inspection opening for every compartment to allow internal maintenance and repair.
* Insulated tanks must have a spill collection reservoir with drains around top fittings.
* Piping must be metallic, use welded joints wherever possible, and be installed to avoid damage from thermal expansion/contraction, shock, and vibration.
* Bottom Openings:
* If prohibited by the applicable T code, your tank must have *no* openings below the maximum liquid level. Closed openings must be welded internally and externally with a plate.
* Tanks carrying specific solid, crystallizable, or highly viscous materials require at least two independent shut-off devices (an external stop-valve close to the shell and a liquid-tight closure like a screw cap or blank flange).
* All other bottom discharge outlets generally require three independent shut-off devices: a self-closing internal stop-valve (operable from above/ground, able to close remotely within 30 seconds for tanks $\ge$ 264.2 gallons), an external stop-valve close to the shell, and a liquid-tight end closure. For certain flammable liquids, oxidizers, or toxic materials, this remote closure must also thermally activate at $\le$ 250 °F.
* Pressure and Vacuum Relief:
* Your tanks must be fitted with at least one pressure relief device.
* Tanks with a capacity of 1,900 liters (501.9 gallons) or more require reclosing-type pressure relief devices sized to prevent rupture from over-pressurization or vacuum.
* Vacuum-relief devices, if installed, must be set to relieve at a vacuum setting no greater than −0.21 bar, and those carrying Class 3 flammable liquids must prevent the immediate passage of flame into the shell (or the shell must withstand an internal explosion).
Ask X3